11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
83
Make sure Liftgate platform is open and resting on the ground before perform-
ing the following step.
WARNING
!
To prevent damage when installing valve cartridges & coils, torque valve
cartridge nut to 30 lbs.-in. max.
CAUTION
2. The “D” solenoid valve (FIG. 78-2) may be
stuck in the “open” position. Remove the “D”
solenoid valve (FIG. 83-1). Next, check
the valve cartridge as follows. Push on
the plunger in the valve by inserting small
screwdriver in the open end (FIG. 83-2).
If the plunger does not move with a smooth,
spring-loaded action (approximately 1/8”)
(FIG. 83-1), replace the valve cartridge.
TYPICAL SOLENOID VALVE
REMOVED & DISASSEMBLED
FIG. 83-1
COIL
VALVE
CARTRIDGE
NUT
CHECKING VALVE CARTRIDGE
FIG. 83-2
VALVE
CARTRIDGE
1/8”
3. Reinstall “D” solenoid valve (if good)
(FIG. 83-1) or a replacement. Torque
valve cartridge to 30 lbs.-ft. and hex
nut to 30 lbs.-in.