PLATFORM WILL NOT UNFOLD
“A” VALVE
(UNFOLDING)
TYPICAL VALVES & ELECTRICAL CONNECTIONS
(PUMP IS SHOWN FROM POWER DOWN
UNIT WITH HOSES)
FIG. 68-1
OPENER (UNFOLDING)
VALVE ADJUSTMENT
Before doing the following procedure, set up guarded area around the platform
to keep people from entering.
WARNING
!
TYPICAL
TERMINAL-1
NOTE: Numbers for the electrical terminals
are not stamped on the valve coil.
Numbers shown in illustration are
for reference only.
TYPICAL
TERMINAL-2
1. Flow of hydraulic fl uid may
be restricted. Turn opener
(unfolding) valve adjustment
(FIGS. 68-1 and 68-2)
counter-clockwise to open
the valve. If necessary, do
the PUMP ASSEMBLY
PRESSURE SETTING
procedure in this section.
2. Check if the “A” valve
(FIGS. 68-1 and 68-2) is
energized. Connect voltmeter
to terminal-1 and terminal-2
as shown in FIGS. 68-1 and
68-2. Activate the UNFOLD
toggle switch and FOLD/
UNFOLD toggle switches.
Correct indication is +11 to
+12.6 volts dc. If indication is
incorrect, check control switch
and wiring to “A” valve (refer
to ELECTRICAL SYSTEM
DIAGRAMS section).
Replace faulty wiring or
control switch as required. If
the voltmeter indicates +11 to
+12.6 volts dc and “A” valve
does not operate, replace “A”
valve.
NOTE: For dual pump system, check secondary pump and motor fi rst.
TROUBLESHOOTING
TYPICAL SOLENOID VALVES
(PUMP IS SHOWN FROM GRAVITY DOWN
UNIT WITH STEEL LINES)
FIG. 68-2
“A” VALVE
(UNFOLDING)
TYPICAL
TERMINAL-1
TYPICAL
TERMINAL-2
OPENER (UNFOLDING)
VALVE ADJUSTMENT