11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
66
PLATFORM WILL NOT FOLD - Continued
TROUBLESHOOTING
“E” VALVE
(3-WAY)
Make sure Liftgate platform is open and resting on the ground before perform-
ing the following step.
WARNING
!
To prevent damage when installing valve cartridges & coils, torque valve
cartridge nut to 30 lbs.-in. max.
CAUTION
4. The “E” solenoid valve (FIGS. 66-1
and 66-2) may be stuck in the “open”
position. Remove the “E” solenoid valve
(FIG. 63-1). Next, check the valve cartridge
as follows. Push on the plunger in the
valve by inserting small screwdriver in the
open end (FIG. 63-2). If the plunger does
not move with a smooth, spring-loaded
action (approximately 1/8”) (FIG. 63-2),
replace the valve cartridge.
TYPICAL SOLENOID VALVES
(PUMP IS SHOWN FROM POWER DOWN
UNIT WITH HOSES)
FIG. 66-1
TYPICAL SOLENOID VALVES
(PUMP IS SHOWN FROM GRAVITY DOWN
UNIT WITH STEEL LINES)
FIG. 66-2
“E” VALVE
(3-WAY)