11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
19
1. Lower the platform to ground level.
Check if tip of the ipover and bot-
tom of the runners touch the ground
at the same time (FIG. 19-1).
TIP OF
PLATFORM
BOTTOM OF
RUNNER
GROUND
TIP AND RUNNER TOUCHING GROUND
FIG. 19-1
RUNNERS NOT TOUCHING
FIG. 19-2
BOTTOM OF
RUNNER
2. If the bottom of the runners are off the
ground, measure the distance “H1
(FIG. 19-2) from the ground to the
bottom of the runners.
Adjustment is not required if
distance “H1” is 1” or less.
If distance “H1” is more than 1”, refer
to the steps that follow to adjust the
platform chains.
”H1”
GROUND
MEASURED “H1”
(AT RUNNER)
ADJUSTMENT METHODS
(
REQUIRED FOR EXPECTED RISE AT TIP)
EXPECTED RISE
“H2” (AT TIP)
ADJUST U-BOLT
(RAISES TIP 0”
TO 1-1/4”)
REMOVE 1 LINK
OF BOTH CHAINS
(RAISES TIP 1-1/2”)
REMOVE 2 LINKS
OF BOTH CHAIN
(RAISES TIP 3”)
1” - 2-1/4”
--0” - 1-1/4”
2-1/2” - 3-3/4”
••
- 1-1/2” - 2-3/4”
4”
••
3” - 4”
TABLE 19-1
3. Refer to measured distance “H1” at the run-
ners and TABLE 19-1. Note the method(s)
that will be required to raise the tip of platform
(or retention ramp) the expected distance.
”H2”
ADJUSTMENT
PLATFORM CHAIN ADJUSTMENT
Personal injury and damaged equipment
could result if chains separate from plat-
form under load. Never adjust the plat-
form chains to compensate for excessive
wear. Refer to chain inspection on the
PERIODIC MAINTENANCE CHECKLIST.
Adjustment should only be necessary
when new chains are installed.
WARNING
!