PLATFORM LOWERS SLOWLY
1. Check if the “B” solenoid valve coil (FIGS.
78-1 and 78-2) (located in the pump
box) is getting power. Connect voltmeter
to terminal-1 and terminal-2 of the coil.
Activate the DOWN toggle switch.
Correct indication is +11 to +12.6 volts
dc. If the voltmeter does not indicate +11
to +12.6 volts dc, check control switch
and wiring to “B” solenoid valve (refer
to ELECTRICAL SYSTEM DIAGRAMS
section). Replace faulty wiring or control
switch as required. If the voltmeter
indicates +11 to +12.6 volts dc and valve
still does not operate, replace the valve.
NOTE: For dual pump system, check secondary pump and motor fi rst.
NOTE: Numbers for the electrical terminals shown in the illustration are not
stamped on valve coil. Numbers shown are for reference only.