PLATFORM RAISES HALFWAY & STOPS
TROUBLESHOOTING
GRAVITY DOWN LIFTGATES: Lower the platform to the ground. Clean dirt and
uid from top of reservoir in pump box. Fill the reservoir to correct level indicated
on sight glass (pump box).
2. Find out if vehicle is equipped with optional battery box, truck charge line, tractor charge
line, or trailer charge line. Check optional battery box cables and charge line cables for
damage, dirty connections and loose connections. Replace damaged battery cables,
clean dirty connections, and tighten loose connections.
3. Check if vehicle batteries and optional battery box batteries are fully charged. If required,
fully charge batteries with a battery charger. Replace batteries that cannot fully charge.
If battery charger fully charges batteries, use vehicle manufacturer’s speci cations to
check the vehicle battery charging system. Do not operate Liftgate if vehicle charging
system needs repair.
4. Check pump motor solenoid (FIGS. 55-1 and 55-2) and electrical cable connections
in
pump box. Make sure electrical cable connections are clean and tight. Use a 6” long,
10 gauge insulated wire as a jumper between motor solenoid terminals “A” and “C” to
activate solenoid. Replace solenoid if it fails to activate.
1. Check the hydraulic uid level in the reservoir.
POWER DOWN LIFTGATES: Raise the platform to bed height. Fill the reservoir to
correct level indicated on sight glass (pump box).
NOTE: For dual pump system, check secondary pump and motor rst.